VESDA stand for very early smoke detection apparatus ;;;; now question raising that very early detect smoke? 🙄 than what device , i mean which devices comparatively are vesda is dominate device. answer is VESDA most efficient than the smoke detector and beam detector ,and all other input devices in fire alarm system even some how a man enter in VESDA protected room with the perfumed it might be activate the fire alarm through VESDA,
when we experiencing and comprising other input devices like smoke detector or beam detector or others like LINEAR HEAT WIRE system those all are static but only vesda is monitoring pin movement in the atmospheric changing , how? se below method of working
actually vesda is compact device having a tiny but good quality fan or we surely may call exhaust fan FIXED inside this fan associated conduit with holes on this pipe surface so it is device of continuously suction the air through a conduit of protected zone , this air passes from 2 no's filters and those filters checking ppm (part per million ) threshold of both filters addresses as first filter monitoring less ppm and second filter activate when amount increases higher , so ! this special type of detection eligible to act instant and alarm
when ppm (part per million) cross then first filter threshold it adressed as stage-1 fire similarly when particles in air cross than the limit from second filter it shows stage-2 fire with main building fire alarm controll panel.
Customers have questions, you have answers. Display the most frequently asked questions, so everybody benefits.
A fire alarm system is a crucial safety feature in buildings and facilities, designed to detect and alert occupants to the presence of a fire or smoke. It plays a vital role in safeguarding lives and property by providing early warning of potential fire hazards. Here are the key components and functions of a typical fire alarm system:
Regular maintenance and testing of a fire alarm system are crucial to ensure its reliability. Fire drills should also be conducted periodically to familiarize occupants with evacuation procedures. Fire alarm systems are a fundamental aspect of fire safety in any building, and their proper installation and maintenance are essential to protect lives and property in the event of a fire.
A pre-action fire alarm system is a sophisticated fire detection and suppression system designed to provide early warning of a potential fire and prevent false activations of the sprinkler system. Its working principle involves several key components and stages:
The key advantage of a pre-action fire alarm system is its ability to provide early detection of a fire while preventing accidental water discharge due to false alarms. This makes it suitable for environments where water damage must be minimized, such as data centers, libraries, museums, and other sensitive areas
A smoke detector is a device that senses the presence of smoke in the air and triggers an alarm to alert occupants of a potential fire. Smoke detectors work based on one of two primary principles: ionization and photoelectric (optical) sensing. Here's how each type works:
Both ionization and photoelectric smoke detectors are effective at detecting different types of fires. Ionization detectors are better at detecting fast, flaming fires with smaller smoke particles, while photoelectric detectors are more sensitive to slow, smoldering fires with larger smoke particles. To provide comprehensive fire protection, many modern smoke detectors use a combination of both ionization and photoelectric sensing technologies, referred to as dual-sensor or dual-sensing smoke detectors. This approach offers a higher level of reliability and can quickly detect a wide range of fire types
A deluge valve plays a crucial role in a pre-action fire sprinkler system, which is designed to provide an added level of protection against accidental or unintended activation of the sprinklers. Here's how a deluge valve works in such a system:
In summary, a deluge valve in a pre-action fire sprinkler system is normally closed, preventing water from entering the sprinkler pipes until a fire is detected. When a fire is sensed, the control panel triggers the deluge valve to open, allowing water to flood the sprinkler pipes, after which individual sprinkler heads open based on heat detection, extinguishing the fire. This added layer of control helps prevent accidental discharges and provides a measure of security in environments where water damage needs to be minimized, such as data centers or museums.